<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">medjournal</journal-id><journal-title-group><journal-title xml:lang="ru">Медицинский журнал</journal-title><trans-title-group xml:lang="en"><trans-title>Medical Journal</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1818-426X</issn><publisher><publisher-name>Белорусский государственный медицинский университет</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.51922/1818-426X.2025.4.118</article-id><article-id custom-type="elpub" pub-id-type="custom">medjournal-376</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОРИГИНАЛЬНЫЕ НАУЧНЫЕ ПУБЛИКАЦИИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ORIGINAL SCIENTIFIC PUBLICATIONS</subject></subj-group></article-categories><title-group><article-title>Анализ прочностных характеристик цементно-винтовой фиксации мульти-юнит абатментов к дентальным имплантатам с плоскостным и коническим типом соединения в эксперименте</article-title><trans-title-group xml:lang="en"><trans-title>ANALYSIS OF STRENGTH CHARACTERISTICS OF CEMENT-SCREW FIXATION OF MULTI-UNIT ABUTMENTS TO DENTAL IMPLANTS WITH FLAT AND CONICAL TYPE OF CONNECTION IN EXPERIMENT</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Прялкин</surname><given-names>С. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Pryalkin</surname><given-names>S. V.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Рубникович</surname><given-names>С. П.</given-names></name><name name-style="western" xml:lang="en"><surname>Rubnikovich</surname><given-names>S. P.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Бусько</surname><given-names>В. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Busco</surname><given-names>V. N.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>УО «Белорусский государственный медицинский университет»</institution></aff><aff xml:lang="en"><institution>Educational Institution «Belarusian State Medical University»</institution></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>«Институт прикладной физики Национальной академии наук Беларуси»</institution></aff><aff xml:lang="en"><institution>Institute of Applied Physics of the National Academy of Sciences of Belarus</institution></aff></aff-alternatives><pub-date pub-type="collection"><year>2025</year></pub-date><pub-date pub-type="epub"><day>25</day><month>12</month><year>2025</year></pub-date><volume>0</volume><issue>4</issue><fpage>118</fpage><lpage>124</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Прялкин С.В., Рубникович С.П., Бусько В.Н., 2025</copyright-statement><copyright-year>2025</copyright-year><copyright-holder xml:lang="ru">Прялкин С.В., Рубникович С.П., Бусько В.Н.</copyright-holder><copyright-holder xml:lang="en">Pryalkin S.V., Rubnikovich S.P., Busco V.N.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://medjournal.ejournal.by/jour/article/view/376">https://medjournal.ejournal.by/jour/article/view/376</self-uri><abstract><p>Цель – провести анализ прочностных характеристик цементно-винтовой фиксации мульти-юнит абатментов к дентальным имплантатам с плоскостным и коническим типом соединения в эксперименте в условиях циклических нагружений, имитирующих функциональные нагрузки в ротовой полости.Методы. Оценивали прочностные характеристики цементно-винтового соединения (ЦВС) мульти-юнит абатментов к дентальным имплантатам из сплава Ti-6Al-4V диаметром 3,75 мм и длиной 11,5 мм с коническим и плоскостным типом соединения. Всего в эксперимент было включено 48 дентальных имплантатов – 24 с плоскостным и 24 с коническим типом соединения. В свою очередь каждые 24 имплантата были распределены на шесть групп в зависимости от экспериментальных условий: три группы при угле нагружения 22,5° и силе воздействия 100 Н с количеством циклов нагружения 100 000, 150 000 и 200 000; три группы при угле нагружения 45° и силе воздействия 100 Н с количеством циклов нагружения 100 000, 150 000 и 200 000.Результаты. При сравнительном анализе прочности экспериментальных образцов в условиях максимальной нагрузки (угол нагружения 45° и 200 000 циклов нагружения) во 2-ом положении импланта, как наиболее слабом элементе всей конструкции, выявлено, что при коническом типе глубина ЦВС снижается на 19 %, а степень зажатия винтов – на 73 % от изначального уровня до нагрузки, в то время как при плоскостном типе аналогичные параметры снижаются на 33 % и 80 % соответственно.Заключение. Установлено, что конический тип соединения является более надёжным нежели плоскостной тип, его использование позволяет повысить сопротивление нагрузкам, так как накопление усталости ортопедических конструкций при коническом мульти-юнит соединении возрастает в 1,2 раза, при плоскостном мульти-юнит соединении – в 1,5 раза. соединения, имитирующего проекцию 2-го премоляра) на 24 % по сравнению с плоскостным типом соединения.</p></abstract><trans-abstract xml:lang="en"><p>Purpose is to analyze the strength characteristics of the cement-screw fixation of multiunit abutments to dental implants with a planar and conical type of connection in an experiment under conditions of cyclic loads simulating functional loads in the oral cavity.Methods. The strength characteristics of the cement-screw connection (CSC) of multiunit abutments to dental implants made of Ti-6Al-4V alloy with a diameter of 3.75 mm and a length of 11.5 mm with a conical and planar type of connection were evaluated. A total of 48 dental implants were included in the experiment – 24 with a planar and 24 with a conical type of connection. In turn, every 24 implants were divided into six groups depending on the experimental conditions: three groups with a loading angle of 22.5° and a force of 100 N with a number of loading cycles of 100 000, 150 000 and 200 000; three groups at loading angle of 45° and impact force of 100 N with number of loading cycles of 100 000, 150 000 and 200 000.Results. In comparative analysis of the strength of experimental samples under maximum load conditions (loading angle of 45° and 200,000 loading cycles) in the 2nd position of the implant, as the weakest element of the entire structure, it was revealed that with the conical type, the depth of the CSC decreases by 19 %, and the degree of screw clamping – by 73 % from the initial level to the load, while with the planar type, similar parameters decrease by 33 % and 80 %, respectively.Conclusion. It has been established that the conical type of connection is more reliable than the planar type, its use allows you to increase the resistance to loads, since the accumulation of fatigue of orthopedic structures with a conical multi-unit connection increases in 1.2 times, with a planar multi-unit connection – in 1.5 times. compound simulating the projection of the 2nd premolar) by 24 % compared to the planar type of compound.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>дентальный имплантат</kwd><kwd>циклические нагружения</kwd><kwd>цементновинтовое соединение</kwd><kwd>ортопедическая конструкция</kwd><kwd>экспериментальная модель</kwd><kwd>мульти-юнит абатменты</kwd></kwd-group><kwd-group xml:lang="en"><kwd>dental implant</kwd><kwd>cyclic loadings</kwd><kwd>cement-screw joint</kwd><kwd>orthopedic construction</kwd><kwd>experimental model</kwd><kwd>multi-unit abutments</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Исследование выполнено в рамках инициативной научно-исследовательской работы «Разработка и внедрение эффективных технологий в стоматологии с использованием дентальной имплантации» (номер госрегистрации 20200407 от 31.03.2020 г., срок выполнения 2020–2022 гг.).</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Pakhshan, G., Zahra B. Multi-Unit Abutment: Why, Where, When? // J. Oral Med. and Dent. Res. – 2025. – Vol. 6, № 2. – P. 1–8.</mixed-citation><mixed-citation xml:lang="en">Pakhshan, G., Zahra B. Multi-Unit Abutment: Why, Where, When? // J. Oral Med. and Dent. Res. – 2025. – Vol. 6, № 2. – P. 1–8.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Андриянова, Н. В. Улучшение конструкции внутрикостного дентального винтового имплантата // Тенденции развития науки и образования. – 2017. – № 33–1. – С. 31–32.</mixed-citation><mixed-citation xml:lang="en">Andriyanova, N. V. Uluchshenie konstrukcii vnutrikostnogo dental’nogo vintovogo implantata // Tendencii razvitiya nauki i obrazovaniya. – 2017. – № 33–1. – S. 31–32.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Farah, R. I., Alshabi A. M. Technique to verify the accuracy of a definitive cast before the fabrication of a fixed dental prosthesis // J. Prosthet. Dent. – 2016. – Vol. 116, № 3. – Р. 325–327.</mixed-citation><mixed-citation xml:lang="en">Farah, R. I., Alshabi A. M. Technique to verify the accuracy of a definitive cast before the fabrication of a fixed dental prosthesis // J. Prosthet. Dent. – 2016. – Vol. 116, № 3. – Р. 325–327.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Baig, M. Multi-unit implant impression accuracy: A review of the literature // Quintessence international. – 2014. – Vol. 45. – P. 39–51. – doi: org/10.3290/j.qi.a30769.</mixed-citation><mixed-citation xml:lang="en">Baig, M. Multi-unit implant impression accuracy: A review of the literature // Quintessence international. – 2014. – Vol. 45. – P. 39–51. – doi: org/10.3290/j.qi.a 30769.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Wu, Y.-L., Aaron Y.-J. W. A method of fabricating an accurate repositioning device for relocating multiple multiunit abutments // The Journal of Prosthetic Dentistry. – 2017. – Vol. 118, № 4. – Р. 564–566.</mixed-citation><mixed-citation xml:lang="en">Wu, Y.-L., Aaron Y.-J. W. A method of fabricating an accurate repositioning device for relocating multiple multiunit abutments // The Journal of Prosthetic Dentistry. – 2017. – Vol. 118, № 4. – Р. 564–566.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Albadani, M., Alahmari M. Full-Mouth Rehabilitation Using Combined Multiunit Abutment and Screw-Retained T-Base Abutment System: A Case Report with 24-Month Followup // Open Dent. J. – 2024. – Vol. 18. – P. e18742106293859. – doi.org/10.2174/0118742106293859240520103643.</mixed-citation><mixed-citation xml:lang="en">Albadani, M., Alahmari M. Full-Mouth Rehabilitation Using Combined Multiunit Abutment and Screw-Retained T-Base Abutment System: A Case Report with 24-Month Followup // Open Dent. J. – 2024. – Vol. 18. – P. e18742106293859. – doi: org/10.2174/0118742106293859240520103643.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Машков, К. Н. Применение дентальных имплантатов при полном отсутствии зубов // Бюллетень медицинских интернет-конференций. – 2019. – Т. 9, № 6. – С. 243–244.</mixed-citation><mixed-citation xml:lang="en">Mashkov, K. N. Primenenie dental’nyh implantatov pri polnom otsutstvii zubov // Byulleten’ medicinskih internet-konferencij. – 2019. – T. 9, № 6. – S. 243–244.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Бусько, В. Н. Лабораторная установка для исследования усталостной повреждаемости плоских ферромагнитных образцов // Приборы и техника эксперимента. – 2011. – № 1. – С. 165–167.</mixed-citation><mixed-citation xml:lang="en">Bus’ko, V. N. Laboratornaya ustanovka dlya issledovaniya ustalostnoj povrezhdaemosti ploskih ferromagnitnyh obrazcov // Pribory i tekhnika eksperimenta. – 2011. – № 1. – S. 165–167</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
